Pioneers in the industry, we offer aurad410030 au rccb 100a fp 415v adi 300ma, aurad404010 au rccb 40a fp 415v adi 100ma, aurad410003 au rccb 100a fp 415v adi 30ma, bg402503 exora rccb 25a fp 415v ac 30ma, legrand 669718 - 100a- 4pole drx 125hp 25ka - mccb and legrand 669714 - 40a- 4pole drx 125hp 25ka - mccb from India.
₹ 4000 / Piece Get Latest Price
| Rated current | 100 A |
| Sensitivity | 300 mA |
| Pole | 4 Pole |
| No. of Poles | Four Pole |
| Voltage | 415V |
| Brand | L&T |
| Model Name/Number | L&T |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (rigid) / 35 Sq. mm (flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 300mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
₹ 2700 / Piece Get Latest Price
| Sensitivity | 100 mA |
| Pole | 4 Pole |
| No. of Poles | Four Pole |
| Voltage | 415V |
| Rated Current | 40 A |
| Brand | L&T |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 40A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 100mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
₹ 4000 / Piece Get Latest Price
| Rated current | 100 A |
| Sensitivity | 30 mA |
| Pole | 4 Pole |
| No. of Poles | Four Pole |
| Voltage | 415V |
| Brand | L&T |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (rigid) / 35 Sq. mm (flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 30mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
₹ 1300 / Piece Get Latest Price
| Sensitivity | 30 mA |
| Pole | 4 Pole |
| Rated Current | 25 A |
| No. of Poles | Four Pole |
| Voltage | 415v |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +55°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (Rigid) 35 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20000 |
| No. of Poles | FP |
| Conformance to standards | IS 12640-1 IEC 61008-1 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1 kA |
| Rated Impulse Voltage | 4kV |
| Rated Conditional SC Current | 10 kA |
| Current Rating | 40A |
| Rated Operational voltage (Ue) | 415V |
| Conformance to Standards | IS 12640-1 IEC 61008-1 |
| Sensitivity | 30mA |
| Length(mm) | 77.1 |
| Height(mm) | 83 |
| Breadth(mm) | 71 |
₹ 4500 / Piece Get Latest Price
| Current Rating | 100A |
| Country of Origin | Made in India |
| Breaking Capacity | 25 kA |
| Category | MCCB |
| Current | 100 Amps |
| Frame Size | DRX 125 |
| Pole | Four Pole |
| Sub Category | DRX |
| Trip Unit | Thermal magnetic |
₹ 4950 / Piece Get Latest Price
| Current Rating | 40 A |
| Poles | 4 Pole |
| Number of Poles | 3 Pole |
| Breaking Capacity | 16kA |
| Country of Origin | Made in India |
| Category | MCCB |
| Current | 40 Amps |
| Sub Category | DRX |
| Type | Thermal Magnetic |
₹ 18500 / Piece Get Latest Price
| Current Rating | 100A |
| Number of Poles | 4 Pole |
| Country of Origin | Made in India |
| Brand | Legrand |
| Breaking Capacity | 25 kA |
| Category | MCCB |
| Current Rating | 100 Amps |
| Frame Size | DPX3 160 |
| Pole | Four Pole |
| Sub Category | DPX3 |
| Trip Unit | Thermal Magnetic With Elcb |
| Type | Adjustable |
₹ 23200 / Piece Get Latest Price
| Number of Poles | 4 Pole |
| Model | DRX MCCBs |
| Country of Origin | Made in India |
| Brand | Legrand |
| Breaking Capacity | 36 kA |
| Category | MCCB |
| Current Rating | 400 Amps |
| Frame Size | DRX 630 |
| Pole | Four Pole |
| Sub Category | DRX |
| Trip Unit | Microprocessor |
| Type | Adjustable |
₹ 8000 / Piece Get Latest Price
| Current Rating | 630 |
| Number of Poles | 3 Pole |
| Model | DRX MCCBs |
| Country of Origin | Made in India |
| Breaking Capacity | 36 kA |
| Category | MCCB |
| Current | 630 Amps |
| Frame Size | DRX 630 |
| Pole | TP |
| Sub Category | DRX |
| Trip Unit | Thermal magnetic |
₹ 16000 / Piece Get Latest Price
| Current Rating | 500 |
| Number of Poles | 4 Pole |
| Model | DRX MCCBs |
| Country of Origin | Made in India |
| Breaking Capacity | 36 kA |
| Category | MCCB |
| Current | 500 Amps |
| Frame Size | DRX 630 |
| Pole | Four Pole |
| Sub Category | DRX |
| Trip Unit | Thermal magnetic |
₹ 500 / Piece Get Latest Price
| Current Rating | 200 A |
| No. of Poles | 4 Poles |
| Poles | 3 Pole |
| Breaking Capacity | 10kA |
| Trip Type | Thermal Magnetic |
The MCCB 250A/3P (Molded Case Circuit Breaker) is engineered for robust circuit protection in medium to high-capacity electrical installations. With a rated current of 250A and 3-pole configuration, it is designed to handle demanding loads in both industrial and commercial environments. Its compact molded case construction ensures durability, while providing high breaking capacity to protect against overloads, short circuits, and equipment faults.
This MCCB offers adjustable trip settings, enabling precise customization for different system requirements. Its thermal-magnetic protection ensures reliable performance under varying load conditions, preventing damage to sensitive electrical equipment. With features such as arc-extinguishing chambers, high dielectric strength, and consistent tripping characteristics, it maintains stability and enhances operational safety in critical applications.
Built for ease of installation and long service life, the MCCB 250A/3P is suitable for panel boards, switchboards, distribution systems, and motor protection setups. Its compliance with international standards ensures reliability, making it a preferred choice for engineers and electricians seeking a dependable circuit protection solution for modern electrical systems.
₹ 7500 / Piece Get Latest Price
| Current Rating | 630 |
| Number of Poles | 3 Pole |
| Breaking Capacity | 32kA |
| Model | DRX MCCBs |
| Country of Origin | Made in India |
| Brand | Legrand |
| Breaking Capacity | 36 kA |
| Category | MCCB |
| Current Rating | 400 Amps |
| Frame Size | DRX 630 |
| Pole | Three Pole |
| Sub Category | DRX |
| Trip Unit | Thermal magnetic |
| Type | Adjustable |
₹ 2250 / Piece Get Latest Price
| Rated Current | 63 A |
| No. of Poles | Four Pole |
| Frequency | 60Hz |
| Brand | L&T |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 63A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 100mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
₹ 2000 / Piece Get Latest Price
| No. of Poles | Four Pole |
| Voltage | 415v |
| Rated Current | 63 A |
| Brand | L&T |
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +55°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (Rigid) 35 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20000 |
| No. of Poles | FP |
| Conformance to standards | IS 12640-1 IEC 61008-1 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1 kA |
| Rated Impulse Voltage | 4kV |
| Rated Conditional SC Current | 10 kA |
| Current Rating | 63A |
| Rated Operational voltage (Ue) | 415V |
| Conformance to Standards | IS 12640-1 IEC 61008-1 |
| Sensitivity | 100mA |
| Length(mm) | 77.1 |
| Height(mm) | 83 |
| Breadth(mm) | 71 |
JYOTI (OWNER)
Aarav Electrical And Marketing
First Floor, B-467/4 , KH. No. 222, Main Market Pusta 1 Sonia Vihar, Main Market Pusta 1
New Delhi - 110094, Delhi, India