Providing you the best range of minilec vsp d2 phase failure relays, lc1d25kue tesys contactor-3p, lc1d12fd tesys3pctr12a ac3 5.5kw1no1nc110vdc coil, lc1d18m7 tesys d contactor - 3p(3 no) - ac-3, lc1g265kuen high power contactor, tesys giga, 3 pole (3no), ac-3 and lc1g400kuen high power contactor, tesys giga, 3 pole (3no) with effective & timely delivery.
₹ 650 / Piece Get Latest Price
| Overall Dimensions (mm) | 76 x 56.5 x 117.5 |
| Mounting Dimensions | 67 x 46 / 35 mm rail Mounting |
| Resetting Mode | Auto / Manual / Remote |
| Weight | 400 gm |
| Brand | Minilec |
₹ 4500 / Piece Get Latest Price
| Rated Current | 25 A |
| Number Of Poles | 3 Pole |
| Rated Voltage | 240 V |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys contactor-3P-AC3- <= 440V 25A - |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 440V AC/DC |
| Number of Poles | 3P |
₹ 3500 / Piece Get Latest Price
| Rated Current | 12 A |
| Number Of Poles | 3 Pole |
| Rated Voltage | 240 V |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys3PCTR12A AC3 5.5KW1NO1NC110VDC COIL |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 110V DC |
| Number of Poles | 3P |
₹ 4000 / Piece Get Latest Price
| Rated Current | 40 A |
| Number Of Poles | 3 Pole |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Range of product | TeSys Deca |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-1 AC-4 AC-3 AC-3e |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
₹ 2500 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Rated Current | 32 A |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Range | TeSys |
|---|---|
| Range of product | TeSys Giga |
| Product or component type | Contactor |
| Device short name | LC1G |
| Contactor application | Power switching Motor control |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5 |
₹ 4500 / Piece Get Latest Price
| Rated Current | 50 A |
| Number Of Poles | 3 Pole |
| Rated Voltage | 240 V |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Range | TeSys |
|---|---|
| Range of product | TeSys Giga |
| Product or component type | Contactor |
| Device short name | LC1G |
| Contactor application | Power switching Motor control |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5 |
₹ 4000 / Piece Get Latest Price
| Number Of Poles | 4 Pole |
| Country of Origin | Made in India |
| Range | TeSys |
|---|---|
| Range of product | TeSys Giga |
| Product or component type | Contactor |
| Device short name | LC1G |
| Contactor application | Power switching |
| Utilisation category | AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5 |
| Poles description | 4P |
₹ 140 / Piece Get Latest Price
| Current Rating | 16A |
| Series | Livia |
| Number of Modules | 1 Module |
| Tripping Curve | C Curve |
| Rated current | 16 A |
| Number of Poles | Single Pole (SP) |
| Product Name | 16A Mini Mcb,Wh |
|---|---|
| Range Name | Livia |
| Tax Class | GST-18 |
| Color | White |
₹ 10000 / Piece Get Latest Price
| Changeover Type | On Load |
| Current Rating | 630A |
| Poles | 4 Pole |
| Phase | Three Phase |
| Rated Current(A) | 630 A |
| Rated Operational Current (A) | 630A |
|---|---|
| Conformance to Standards | IS/IEC 60947-3, EN 60947-3 |
| Utilization Category | AC-23A |
| Rated operational voltage (Ue) | 690V |
| Operating Frequency(Hz) | 50/60 |
| Mechanical Life (No. of operating cycles) | 20000 |
| Rated Insulation Voltage Ui (V) | 1250V |
| Short Time Withstand for 1sec (kA) | 20 |
| Rated Breaking Capacity@AC-23A (A) | 5000 |
| Rated Making Capacity@AC-23A (A) | 6300 |
| Version | Open Execution |
| No. of Poles | 4P |
| Maximum Al termination (sq.mm) | 2 X 300 |
| Mounting positions | All Orientations |
| Standard Accessories | Terminal Shrouds, Phase Barriers, Extended handle with shaft |
| Pollution Degree | 3 |
| Discount Percentage | Between 0-10 % |
₹ 650 / Piece Get Latest Price
| Overall Dimensions (mm) | 90 x 35 x 60 |
| Mounting Dimensions | 35 mm Rail Mounting |
| Resetting Mode | Auto Reset |
| Brand | Minilec |
| Model No./Name | S2 VMR2 |
| Auxillary | Built In (from 3 Phase) |
| Output Contacts | 2 CO |
| Weight | 100g |
₹ 650 / Piece Get Latest Price
| Sensing Voltage | 415V AC |
| Mounting Type | DIN rail or panel mounting |
| Monitoring Function | Phase failure, phase reversal, and phase unbalance detection |
| Brand | Minilec |
| Operating Voltage | 415V AC |
PHASE FAILURE RELAYS
These relays are suitable for monitoring incoming 3-phase supply from Mains (Electricity distribution line). Being independent of load, they can be used for any HP/KW rating of load.
FEATURES
Fixed/adjustable unbalance settings
Fixed/adjustable undervoltage/over-voltage settings
Fixed/adjustable trip delays
Built-in or external power supply
Resetting Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail, Plug-in)
Models with Micro-Controller based design
Use of SMD Technology
User-friendly LED indications
MODELS:-
VSP D1, VSP D2, S1 VMR7 ,P1 PFS2 , S2 VMR1, S2 VMR2 , HLV D2 , ALV D2 , VMR D2 , D1 HL S1 ,
VST D1 , D1 VMR1, D2 VMR1, D2 VMR2 ,S2 VMR3 ,VPG D1 ,S2 VMR6,
₹ 350 / Piece Get Latest Price
| Overall Dimensions (mm) | 76 x 30.5 x 117.5 |
| Mounting Dimensions | 68 centre to centre/ 35 mm rail Mounting |
| Resetting Mode | Auto |
| Brand | Minilec |
| Model | VSP D1 |
| Weight | 320 gm |
Supply Voltage
Output Contacts
Trip Setting(Volts)
Trip Time Delay
Resetting Mode
Weight
Dimensions (mm)
Note:
Suitable for Panels in Following Apllications:
₹ 3500 / Piece Get Latest Price
| Current Rating | 16 |
| Voltage | 220-240 V |
| Number Of Poles | 3 Pole |
| No. of Poles | 3 Pole |
| Phase | Three Phase |
| Product Name | 3P CONT 16A AC3 7.5KW 1NC AUX 220VAC COI |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys K |
| Coil Voltage | 220V AC |
| Number of Poles | 3P |
₹ 3000 / Piece Get Latest Price
| Rated Current | 80 A |
| Number Of Poles | 3 Pole |
| Rated Voltage | 240 V |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Product Name | CONTACTOR |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys D |
| Coil Voltage | 220V DC |
| Number of Poles | 3P |
₹ 3000 / Piece Get Latest Price
| Rated Current | 32 A |
| Number Of Poles | 3 Pole |
| Rated Voltage | 240 V |
| Pole Type | 3 Pole |
| Country of Origin | Made in India |
| Product Name | CONTACTOR |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 115V AC |
| Number of Poles | 3P |
₹ 17500 / Piece Get Latest Price
| Rated Current | 40 A |
| No. of Poles | 4 Poles |
| Current Rating | 40 |
| Number of Poles | 4 Pole |
| Model Name/Number | L&T |
| Breaking Capacity | 25 kA |
| Rated Operational Current | 40 |
|---|---|
| Mechanical Life (No. of operating cycles) | 30000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | iTRP1 |
| Rated Short Circuit Breaking capacity Icu(kA) | DZ1D MCCB 40 4P 415V AC 36kA iTRP1 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 36kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 10000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 3650 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Product Name | EasyPact TVS contactor 3P(3 NO) - AC-3 - 400 V 25A - 220 V AC coil wide range |
|---|---|
| Tax Class | GST-18 |
| Range Name | Easypact TVS |
| Coil Voltage | 220V AC |
| Number of Poles | 3P |
₹ 4500 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys3PCTR38A AC3 18.5KW1NO1NC220VDC COI |
|---|---|
| Range Name | TeSys D |
| Number of Poles | 3P |
| Tax Class | GST-18 |
₹ 3500 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Range | TeSys |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| Contactor application | Motor control |
| Utilisation category | AC-3 AC-3e AC-4 |
|---|---|
| Poles description | 3P |
| power pole contact composition | 3 NO |
₹ 3000 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Range | TeSys |
|---|---|
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-4 AC-1 AC-3 AC-3e |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC |
₹ 3999 / Piece Get Latest Price
| Motor Power | 15 HP |
| Phase | Three Phase |
| Current Rating | 9 A |
| Voltage | 240V |
| Rated Voltage | 230 V |
| Application | Submersible Pump |
| Relay Range (A) | 9-15A |
|---|---|
| Relay | MN 2 |
| Contactor | MNX 25 |
| Coil Voltage | 240 V AC |
| Conformance to Standards | IS/IEC 60947-4-1, IEC 60947-4-1 |
| Ambient temperature | -5 to 55 deg C |
| Degree of protection | IP 54 |
| Discount Percentage | Between 0-10 % |
₹ 4500 / Piece Get Latest Price
| Rated Current | 32 A |
| Number Of Poles | 4 Pole |
| Rated Voltage | 240 V |
| Pole Type | 4 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys 4P CTR 32A AC1 2NO 2NC 220VAC COIL |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 220V AC |
| Number of Poles | 4P |
₹ 4500 / Piece Get Latest Price
| Number Of Poles | 4 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 110 V DC standard coil |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys D |
| Coil Voltage | 110V DC |
| Number of Poles | 4P |
₹ 3500 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Product Name | Tesys3Pevlk Rever Ctr40A18,5Kwac3 110Vac |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 110V AC |
| Number of Poles | 3P |
₹ 4500 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Product Name | TeSys CTR 32A AC3 15KW 1NO1NC230VAC COIL |
|---|---|
| Tax Class | GST-18 |
| Range Name | TeSys |
| Coil Voltage | 230V AC |
| Number of Poles | 3P |
₹ 3000 / Piece Get Latest Price
| Number Of Poles | 3 Pole |
| Country of Origin | Made in India |
| Range of product | TeSys Deca |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-1 AC-4 AC-3 AC-3e |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
₹ 23000 / Piece Get Latest Price
| No. of Poles | 3 Poles |
| Model Name/Number | L&T |
| Rated Operational Current | 400 |
|---|---|
| Mechanical Life (No. of operating cycles) | 15000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | MTX2.0 |
| Rated Short Circuit Breaking capacity Icu(kA) | DN3-400D MCCB 400 3P 415V AC 36kA MTX2.0 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 36kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 4000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 140 |
| Height(mm) | 266 |
| Depth(mm) | 111.5 |
₹ 15700 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Breaking Capacity | 36kA |
| Rated Operational Current | 250 |
|---|---|
| Mechanical Life (No. of operating cycles) | 25000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | MTX1.0 |
| Rated Short Circuit Breaking capacity Icu(kA) | DN2D MCCB 250 3P 415V AC 36kA MTX1.0 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 36kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 10000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 105 |
| Height(mm) | 179 |
| Depth(mm) | 96 |
₹ 22000 / Piece Get Latest Price
| No. of Poles | 4 Poles |
| Model Name/Number | L&T |
| Country of Origin | Made in India |
| Rated Operational Current | 400 |
|---|---|
| Mechanical Life (No. of operating cycles) | 15000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | TM |
| Rated Short Circuit Breaking capacity Icu(kA) | DN3-400N MCCB 400 4P 415V AC 50kA Thermal Magnetic 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 4000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 183.5 |
| Height(mm) | 266 |
| Depth(mm) | 111.5 |
₹ 17000 / Piece Get Latest Price
| No. of Poles | 3 Poles |
| Model Name/Number | L&T |
| Country of Origin | Made in India |
| Rated Operational Current | 400 |
|---|---|
| Mechanical Life (No. of operating cycles) | 15000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | TM |
| Rated Short Circuit Breaking capacity Icu(kA) | DN3-400N MCCB 400 3P 415V AC 50kA Thermal Magnetic 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 4000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 140 |
| Height(mm) | 266 |
| Depth(mm) | 111.5 |
₹ 17000 / Piece Get Latest Price
| No. of Poles | 3 Poles |
| Model Name/Number | L&T |
| Rated Operational Current | 320 |
|---|---|
| Mechanical Life (No. of operating cycles) | 10000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | TM |
| Rated Short Circuit Breaking capacity Icu(kA) | DN3B MCCB 320 3P 415V AC 36kA Thermal Magnetic 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 36kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 4000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 140 |
| Height(mm) | 205 |
| Depth(mm) | 111 |
₹ 3700 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Current Rating | 160A |
| Country of Origin | Made in India |
| Rated Operational Current | 160A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | SD |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 75 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 3700 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Current Rating | 100A |
| Country of Origin | Made in India |
| Rated Operational Current | 100A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | SD |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 75 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 3000 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Current Rating | 100A |
| Breaking Capacity | 50kA |
| Country of Origin | Made in India |
| Rated Operational Current | 100A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 50kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 0.25 |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 75 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 5000 / Piece Get Latest Price
| Number of Poles | 4 Pole |
| Current Rating | 80A |
| Breaking Capacity | 36kA |
| Country of Origin | Made in India |
| Rated Operational Current | 80A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 36kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 0.5 |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 5000 / Piece Get Latest Price
| Number of Poles | 4 Pole |
| Current Rating | 32A |
| Breaking Capacity | 36kA |
| Country of Origin | Made in India |
| Rated Operational Current | 32A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 36kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 0.5 |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 4000 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Current Rating | 25A |
| Breaking Capacity | 36kA |
| Country of Origin | Made in India |
| Rated Operational Current | 25A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 36kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 0.5 |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 75 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 5000 / Piece Get Latest Price
| Number of Poles | 4 Pole |
| Current Rating | 50A |
| Breaking Capacity | 25kA |
| Country of Origin | Made in India |
| Rated Operational Current | 50A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 25kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 1 |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 12000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
₹ 2500 / Piece Get Latest Price
| Number of Poles | 3 Pole |
| Current Rating | 25A |
| Breaking Capacity | 18kA |
| Country of Origin | Made in India |
| Rated Operational Current (A) | 25A |
|---|---|
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 18KA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 100% |
| Ambient temperature | -5°C to 55°C |
| Conformance to Standards | IS 60947-2, IEC 60947-2 & EN 60947-2 |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| Mechanical Life (Operating Cycles) | 40000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 75 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
| Discount Percentage | Between 0-10 % |
₹ 12080 / Piece Get Latest Price
| Number of Poles | 4 Pole |
| Current Rating | 320A |
| Breaking Capacity | 50kA |
| Country of Origin | Made in India |
| Rated Operational Current (A) | 320A |
|---|---|
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 690V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 50kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50% |
| Ambient temperature | -5°C to 55°C |
| Conformance to Standards | IS 60947-2, IEC 60947-2 & EN 60947-2 |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 4000 |
| Mechanical Life (Operating Cycles) | 10000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 184 |
| Height(mm) | 205 |
| Depth(mm) | 110.5 |
| Discount Percentage | Between 0-10 % |
JYOTI (OWNER)
Aarav Electrical And Marketing
First Floor, B-467/4 , KH. No. 222, Main Market Pusta 1 Sonia Vihar, Main Market Pusta 1
New Delhi - 110094, Delhi, India